TeSys GV motor circuit breaker, 3 poles (3P), 18A/690V, for 3-phase motor applications 7.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 13-18A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by rotary knob guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
Range | TeSys Deca |
---|---|
Product name | TeSys GV2 TeSys Deca |
Product or component type | Motor circuit breaker |
Device short name | GV2P |
Device application | Motor protection |
Trip unit technology | Thermal-magnetic |
Product Dimensions:
- L:4.8cm x W:9.3cm x H: 4.8cm
GV2P20 - Motor Breaker GV2 3P 13-18A by Schneider Electric
Poles description 3P Network type AC Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 2 x M4 screws)Motor power kW 7.5 kW at 400/415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
15 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 18 A Thermal protection adjustment range 13…18 A conforming to IEC 60947-4-1 Magnetic tripping current 223 A [Ith] conventional free air thermal current 18 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6 Power dissipation per pole 2.5 W Mechanical durability 100000 cycles Electrical durability 100000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 1.7 N.m - on screw clamp terminal Width 45 mm Height 89 mm Depth 97 mm Colour Dark grey