- Symbol:
- 00995685
- 00995686
- 00997331
- Approval:
- RCM trademark
- c UL us listed (OL)
- CE mark (see declaration of conformity):
- To EU EMC Directive
- In accordance with EU RoHS Directive
- CE marking (see declaration of conformity):
- To UK instructions for EMC
- To UK RoHS instructions
- Certificate issuing authority: UL E322346
- Note on materials: RoHS-compliant
- Measured variable: Relative pressure
- Measurement method: Piezoresistive pressure sensor
- Start value for pressure measuring range: -0.1 MPa
- Start value for pressure measuring range: -1 bar
- Start value for pressure measuring range: -14.5 psi
- End value for pressure measuring range: 1.6 MPa
- End value for pressure measuring range: 16 bar
- End value for pressure measuring range: 232 psi
- Max. overload pressure: 5 bar ... 20 bar
- Operating medium:
- Compressed air to ISO 8573-1:2010 [7:4:4]
- Inert gases
- Note on operating and pilot medium: Lubricated operation possible
- Media temperature: 0 °C ... 50 °C
- Ambient temperature: 0 °C ... 50 °C
- Accuracy in ± % FS: 1.5 %FS
- Repetition accuracy in ± %FS: 0.3 %FS
- Temperature coefficient in ± %FS/K: 0.05 %FS/K ... 0.1 %FS/K
- Switching output:
- 2 x PNP or 2 x NPN, switchable
- PNP/NPN, switchable
- Switching function:
- Window comparator
- Threshold value comparator
- Auto difference monitoring
- Switching element function: N/C or N/O contact, switchable
- Max. output current: 80 mA ... 100 mA
- Analogue output:
- 0 - 10 V
- 4 - 20 mA
- 1 - 5 V
- Max. load resistance current output: 500 Ohm
- Min. load resistance voltage output: 20 kOhm
- Short circuit current rating: yes
- Protocol: IO-Link®
- IO-Link, Protocol version: Device V 1.1
- IO-Link, Profile: Smart sensor profile
- IO-Link, Function classes:
- Binary data channel (BDC)
- Process data variable (PDV)
- Identification
- Diagnostics
- Teach channel
- IO-Link, communication mode: COM2 (38.4 kBaud)
- IO-Link, SIO-Mode support: Yes
- IO-Link, Port class: A
- IO-Link, Process data length OUT: 0 bytes
- IO-Link, Process data length IN: 2 bytes
- IO-Link, Process data content IN:
- 14 bit PDV (pressure measurement value)
- 2 bit BDC (pressure monitoring)
- IO-Link, Min. cycle time: 3 ms
- IO-Link, Data storage required: 500 Byte
- Operational voltage range DC: 10.8 V ... 30 V
- Reverse polarity protection: For all electrical connections
- Electrical connection 1, connection type: Plugs
- Electrical connection 1, connector system: Connection pattern L1J
- Electrical connection 1, number of connections/cores: 4
- Electrical connection 1, connection pattern: 00995428
- Type of mounting:
- Front panel mounting
- Via thread Via wall/surface bracket
- Mounting position: optional
- Pneumatic connection:
- Male thread G1/8
- Male thread R1/8
- Male thread 1/8 NPT
- Female thread M5
- Female thread G1/8
- For tubing O.D. 4 mm
- Product weight: 21 g ... 46 g
- Material housing: PA-reinforced
- Material in contact with the medium:
- Anodised wrought aluminium alloy
- FPM
- NBR
- PA-reinforced
- High-alloy stainless steel
- Display type: Illuminated LCD
- Displayable unit:
- sMPa
- bar
- inH2O
- inHg
- kPa
- kgf/cm²
- mbar
- mmHg
- psi
- Setting options: IO-Link® Teach-in Via display and keys
- Protection against tampering:
- IO-Link
- PIN code
- Setting range threshold value: 0 % ... 100 %
- Setting range hysteresis: 0 % ... 90 %
- Degree of protection: IP40
- Corrosion resistance class CRC: 2 - Moderate corrosion stress
- LABS (PWIS) conformity: VDMA24364-B1/B2-L
Festo Pressure sensor SPAN-PIOR-G18M-PNVBA-L1
SKU: F6-2-2
R1 867,99Price
No Reviews YetShare your thoughts.