top of page
  • Symbol:
    • 00995685
    • 00995686
    • 00997331
  • Approval:
    • RCM trademark
    • c UL us listed (OL)
  • CE mark (see declaration of conformity):
    • To EU EMC Directive
    • In accordance with EU RoHS Directive
  • CE marking (see declaration of conformity):
    • To UK instructions for EMC
    • To UK RoHS instructions
  • Certificate issuing authority: UL E322346
  • Note on materials: RoHS-compliant
  • Measured variable: Relative pressure
  • Measurement method: Piezoresistive pressure sensor
  • Start value for pressure measuring range: -0.1 MPa
  • Start value for pressure measuring range: -1 bar
  • Start value for pressure measuring range: -14.5 psi
  • End value for pressure measuring range: 1.6 MPa
  • End value for pressure measuring range: 16 bar
  • End value for pressure measuring range: 232 psi
  • Max. overload pressure: 5 bar ... 20 bar
  • Operating medium:
    • Compressed air to ISO 8573-1:2010 [7:4:4]
    • Inert gases
  • Note on operating and pilot medium: Lubricated operation possible
  • Media temperature: 0 °C ... 50 °C
  • Ambient temperature: 0 °C ... 50 °C
  • Accuracy in ± % FS: 1.5 %FS
  • Repetition accuracy in ± %FS: 0.3 %FS
  • Temperature coefficient in ± %FS/K: 0.05 %FS/K ... 0.1 %FS/K
  • Switching output:
    • 2 x PNP or 2 x NPN, switchable
    • PNP/NPN, switchable
  • Switching function:
    • Window comparator
    • Threshold value comparator
    • Auto difference monitoring
  • Switching element function: N/C or N/O contact, switchable
  • Max. output current: 80 mA ... 100 mA
  • Analogue output:
    • 0 - 10 V
    • 4 - 20 mA
    • 1 - 5 V
  • Max. load resistance current output: 500 Ohm
  • Min. load resistance voltage output: 20 kOhm
  • Short circuit current rating: yes
  • Protocol: IO-Link®
  • IO-Link, Protocol version: Device V 1.1
  • IO-Link, Profile: Smart sensor profile
  • IO-Link, Function classes:
    • Binary data channel (BDC)
    • Process data variable (PDV)
    • Identification
    • Diagnostics
    • Teach channel
  • IO-Link, communication mode: COM2 (38.4 kBaud)
  • IO-Link, SIO-Mode support: Yes
  • IO-Link, Port class: A
  • IO-Link, Process data length OUT: 0 bytes
  • IO-Link, Process data length IN: 2 bytes
  • IO-Link, Process data content IN:
    • 14 bit PDV (pressure measurement value)
    • 2 bit BDC (pressure monitoring)
  • IO-Link, Min. cycle time: 3 ms
  • IO-Link, Data storage required: 500 Byte
  • Operational voltage range DC: 10.8 V ... 30 V
  • Reverse polarity protection: For all electrical connections
  • Electrical connection 1, connection type: Plugs
  • Electrical connection 1, connector system: Connection pattern L1J
  • Electrical connection 1, number of connections/cores: 4
  • Electrical connection 1, connection pattern: 00995428
  • Type of mounting:
    • Front panel mounting
    • Via thread Via wall/surface bracket
  • Mounting position: optional
  • Pneumatic connection:
    • Male thread G1/8
    • Male thread R1/8
    • Male thread 1/8 NPT
    • Female thread M5
    • Female thread G1/8
    • For tubing O.D. 4 mm
  • Product weight: 21 g ... 46 g
  • Material housing: PA-reinforced
  • Material in contact with the medium:
    • Anodised wrought aluminium alloy
    • FPM
    • NBR
    • PA-reinforced
    • High-alloy stainless steel
  • Display type: Illuminated LCD
  • Displayable unit:
    • sMPa
    • bar
    • inH2O
    • inHg
    • kPa
    • kgf/cm²
    • mbar
    • mmHg
    • psi
  • Setting options: IO-Link® Teach-in Via display and keys
  • Protection against tampering:
    • IO-Link
    • PIN code
  • Setting range threshold value: 0 % ... 100 %
  • Setting range hysteresis: 0 % ... 90 %
  • Degree of protection: IP40
  • Corrosion resistance class CRC: 2 - Moderate corrosion stress
  • LABS (PWIS) conformity: VDMA24364-B1/B2-L

Festo Pressure sensor SPAN-PIOR-G18M-PNVBA-L1

SKU: F6-2-2
R1 867,99Price
    No Reviews YetShare your thoughts. Be the first to leave a review.