Schneider Electric TeSys Control Relay 5NO 24VDC - CAD50BD
SKU: C9-4-1 & C9-4-2
R1 129,99 Regular Price
R1 101,74Sale Price
Only 6 left in stock
Range TeSys
TeSys DecaProduct name TeSys CAD Product or component type Control relay device short name CAD contactor application Control circuit Utilisation category AC-14
DC-13
AC-15Pole contact composition 5 NO [Ue] rated operational voltage <= 690 V AC 25...400 Hz Control circuit type DC standard [Uc] control circuit voltage 24 V DC [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 [Ith] conventional free air thermal current 10 A (at 60 °C) Irms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1[Icw] rated short-time withstand current 100 A - 1 s
120 A - 500 ms
140 A - 100 msAssociated fuse rating 10 A gG conforming to IEC 60947-5-1 [Ui] rated insulation voltage 600 V UL certified
600 V CSA certified
690 V conforming to IEC 60947-5-1Mounting support Rail
PlateConnections - terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endTightening torque 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2Control circuit voltage limits 0.1...0.25 Uc (-40…70 °C):drop-out DC
0.7...1.25 Uc (-40…60 °C):operational DC
1...1.25 Uc (60…70 °C):operational DCOperating time 53...72 ms coil energisation and NO closing
16...24 ms coil de-energisation and NO openingMechanical durability 30 Mcycles Maximum operating rate 180 cyc/mn Time constant 28 ms Inrush power in W 5.4 W (at 20 °C) Hold-in power consumption in W 5.4 W at 20 °C Minimum switching voltage 17 V Minimum switching current 5 mA Non-overlap time 1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contactInsulation resistance > 10 MOhm Mechanical robustness Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Height 77 mm Width 45 mm Depth 93 mm Net weight 0.58 kg Standards EN/IEC 60947-5-1
GB/T 14048.5
UL 60947-5-1
CSA C22.2 No 60947-5-1
JIS C8201-5-1product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCAIP degree of protection IP2X front face conforming to VDE 0106 Protective treatment TH conforming to IEC 60068 Ambient air temperature for operation -40…60 °C
60…70 °C with deratingAmbient air temperature for storage -60…80 °C Operating altitude 0...3000 m Height 5.000 cm Width 9.200 cm Length 11.200 cm 18 months
No Reviews YetShare your thoughts.